Hotline:0755-22277778
Tel:0755-22277778
Mobile:13826586185(Mr.Duan)
Fax:0755-22277776
E-mail:duanlian@xianjinyuan.cn
PET silver plated film has a wide range of applications in various fields, and the hardness and wear resistance of its coating are key factors affecting product quality and service life. WhenPET silver plated filmWhen the hardness of the coating does not meet the standard, it will have a series of specific and significant effects on the wear resistance. A deeper understanding of these impacts can help us better evaluate product performance, optimize production processes, and improve product quality.
Hardness is the ability of a material to resist local deformation, especially plastic deformation, indentation, or scratches. For PET silver plated film, the hardness of the coating is an important indicator to measure its resistance to external mechanical forces. The wear resistance reflects the ability of a material to maintain its own performance and integrity under conditions such as friction and wear. Generally speaking, the higher the hardness of the coating, the better its wear resistance. This is because coatings with higher hardness can better resist the stress generated during friction, reduce the detachment and damage of surface materials, and thus extend the wear resistance life of the material.
When the hardness of PET silver plated film coating does not meet the standard, the atoms or molecules on the surface of the coating are more prone to displacement and detachment when subjected to friction. For example, when in contact with other surfaces and sliding relative to each other, coatings with insufficient hardness cannot effectively resist friction, accelerating the wear process. Compared to coatings that meet hardness standards, the wear rate may increase exponentially when the hardness does not meet the standards. This means that under the same usage conditions, the silver plated film will show wear marks faster, shortening its service life in practical applications.
Due to the accelerated wear rate,PET silver plated filmThe wear resistance life will be significantly reduced. In some application scenarios that require high wear resistance, such as touch screen protectors for electronic devices and reflectors in optical instruments, silver plated films with substandard hardness may lose their original performance in a short period of time due to wear and tear. For example, the silver plating layer of the touch screen protective film has insufficient hardness. After multiple touch operations, the silver plating layer will quickly wear out, resulting in a decrease in the conductivity, reflectivity, and other performance of the screen, which affects the normal use of the device.
Failure to meet the hardness standard will rapidly deteriorate the surface smoothness of PET silver plated film during the wear resistance process. During the friction process, coatings with lower hardness are prone to defects such as scratches and pits, which can damage the flatness of the silver plated film surface. The decrease in surface smoothness not only affects the appearance quality of silver plated films, but also further affects their optical and electrical properties. For example, in optical applications, a decrease in surface smoothness can lead to increased light scattering, reduced uniformity of reflectivity and transmittance, and affect imaging quality.
During the wear process, inadequate hardness affects the adhesion between the coating and the PET substrate. With the continuous action of friction, the coating may experience local or large-scale peeling. The peeling of the coating not only further deteriorates the wear resistance of the silver plated film, but may also cause the silver plated film to lose its original function. For example, in electromagnetic shielding applications, coating peeling can damage conductive pathways, reduce electromagnetic shielding effectiveness, and make equipment unable to effectively resist electromagnetic interference.
Failure to meet hardness standards can lead toPET silver plated filmThe surface properties of the object undergo changes, which in turn alter the friction coefficient between it and the object in contact. The change of friction coefficient may bring a series of adverse effects, such as instability of friction coefficient leading to operational inaccuracy in some applications that require precise control of friction force. Moreover, an increase in the friction coefficient may further intensify the wear process, forming a vicious cycle and accelerating the damage of the silver plating film.
In a certain electronic device manufacturing enterprise, a smartwatch produced by it usesPET silver plated filmAs the conductive and reflective layer of the screen. After using the product for a period of time, some users have reported that there are obvious signs of wear and tear on the screen, resulting in a deterioration of the display effect and a lack of sensitivity in touch operations. After testing, it was found that the hardness of the coating on this batch of PET silver plated film did not meet the design standards. Due to insufficient hardness, the surface of the silver plated film rapidly wears out during daily use, resulting in a decrease in surface smoothness and affecting the optical performance of the screen; Meanwhile, the peeling of the coating leads to a decrease in conductivity, which in turn affects the accuracy of touch operations. This case fully illustrates the serious impact of PET silver plated film coating hardness not meeting the standard on wear resistance, as well as the quality problems it brings to the product.
The hardness of PET silver plated film coating does not meet the standard, which has various specific effects on wear resistance, including accelerating wear rate, reducing wear life, affecting surface smoothness, causing coating peeling, and changing friction coefficient. These impacts can lead to decreased product performance and frequent quality issues in practical applications, seriously affecting the market competitiveness and user experience of the product. Therefore, in the production and use of PET silver plated film, it is necessary to attach great importance to the control of coating hardness. By optimizing the production process, strict quality testing and other means, the coating hardness can be ensured to meet the standard, thereby improving the wear resistance of PET silver plated film and ensuring the quality and reliability of the product.
The above data is for reference only, and specific performance may vary due to production processes and product specifications.
Advanced Institute (Shenzhen) Technology Co., Ltd, © two thousand and twenty-onewww.leird.cn. All rights reservedGuangdong ICP No. 2021051947-1 © two thousand and twenty-onewww.xianjinyuan.cn. All rights reservedGuangdong ICP No. 2021051947-2